  • Can I roll a Wye to 45 degrees? - Love Plumbing Remodel
    Yes Ideally the inlet of a wye will be anywhere from right on top to 45 degrees to either side of the top Given proper pitch, it can be rolled all the way down to 90 degrees from the top, but that is usually avoided
  • 45 in a sewer line - DIY Home Improvement Forum
    By code, can I drop my sewer line at 45 degrees, or do I need to drop it at 90 and install a clean out above it? (This is outside the house, on my way to the septic tank ) My land slopes faster than 1 4" ft and I need to keep the 4" pipe at least 4' deep Thanks
  • Changes in Direction of Drainage Flow | UpCodes
    Horizontal drainage lines, connecting with a vertical stack, shall enter through 45 degree (0 79 rad) wye branches, 60 degree (1 05 rad) wye branches, combination wye and one-eighth bend branches, sanitary tee or sanitary tapped tee branches, or other approved fittings of equivalent sweep
  • can I go straight into a wye like this? | Plumbing Forums . . .
    Depending on how an inspector reads the code, this can be done with a Sanitary tee on its back Just roll is at 45 degrees towards the existing vent line, add a street 45, and you will have a proper vent for the toilet
  • Question on Cleanouts for 115 ft. run of 4 inch Schedule 40 connecting . . .
    Cleanouts shall be installed at each change of direction greater than 45 degrees (0 79 rad) in the building sewer, building drain and horizontal waste or soil lines
  • Another plumbing question. . . - Fine Homebuilding
    How do you plumbers feel about wyes feeding into a horizontal drain line with the wye laying on it’s side rather than at 45 degrees or more? Is it legal? […]
  • Number of bends in sanitary drain pipe - Contractor Talk
    This means 7 90 degree bends between the ceiling of the first floor and the cleanout above the basement slab I don't know how many times it has bent in the ceiling of the first floor 45's are possible, it will just increase the size of the bulk-head
  • No storm water ground water is permitted to drain into the sanitary . . .
    No storm water or ground water is permitted to drain into the sanitary sewer system No pipe smaller than 4” diameter is permitted for the building sewer No bend greater than 45 degrees can be used on the sewer system
  • Maximum recommended slope for a sewer line? - Plumbing Zone
    Minimum slopes are required by code for drain pipes depending on the size but not a maximum Sewer lines however can have problems with steep slopes causing solids to be left behind during a flush I understand that any slope over 45 degrees is safe to use but what would be the maximum slope you can safely use without having this problem?